Fire & Smoke Dampers

Available125 products

Fire and smoke dampers automatically close when temperatures reach a certain point to prevent the spread of smoke and fire through the duct system. They use a fusible link that melts above a specific temperature, releasing a spring-loaded damper or blade that blocks smoke and fire from moving through the duct.

Rectangular Fire Dampers

Rectangular Fire Dampers

Rectangular fire dampers have a fusible link that triggers above a specific temperature and closes shut using spring-loaded blades or gates. They eliminate the spread of fire through the HVAC systems.

Static

Static dampers will close in the event of a fire but cannot overcome the blower airflow. If the HVAC system shuts down during a fire, these are suitable. If the HVAC system stays active during a fire, dynamic fire dampers are recommended.

Loading...

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Rectangular Motorized Smoke Dampers

Rectangular Motorized Smoke Dampers

Rectangular motorized smoke dampers close and seal HVAC ducts when their power supply is interrupted. These units feature an electric actuator that holds the damper open when electrical power is connected. This actuator swings closed automatically when it loses power and blocks the spread of smoke through the ducts.

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Rectangular Motorized Fire & Smoke Dampers

Rectangular Motorized Fire & Smoke Dampers

Rectangular motorized fire and smoke dampers have a fusible link and electric actuator that automatically close the damper when power is lost or the temperature exceeds the trigger point. These dampers eliminate the spread of smoke and flames in HVAC systems.

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Round Fire Dampers

Round Fire Dampers

Round fire dampers install into HVAC ducts and feature a fusible link that triggers above a specific temperature and closes shut using spring-loaded blades or gates. These dampers eliminate the spread of fire through the HVAC systems.

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Round Motorized Smoke Dampers

Round Motorized Smoke Dampers

Round motorized smoke dampers connect to round HVAC ducts and seal them when their power supply is interrupted. These dampers feature an electric actuator that holds the damper open when electrical power is connected. This actuator swings closed automatically when it loses power and blocks the spread of smoke through the HVAC system.

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Round Motorized Fire & Smoke Dampers

Round Motorized Fire & Smoke Dampers

Round motorized fire and smoke dampers have a fusible link and electric actuator that automatically close the damper when power is lost or the temperature exceeds the trigger point. These dampers eliminate the spread of smoke and flames in HVAC systems.

Dynamic

Dynamic dampers will close in the event of a fire, even if the HVAC system is operating. They feature mechanisms that are strong enough to close the damper and stay closed, even with the blower running at full speed.

Loading...

Fire Damper Retaining Angles

Fire Damper Retaining Angles
These retaining angles connect to fire dampers and allow for vertical or horizontal installations. They have pre-drilled mounting holes on their sides to position dampers where needed.
Loading...

Replacement Fusible Links

Replacement Fusible Links

Replacement fusible links install into fire dampers and replace links that have been triggered or damaged.

Rectangular Damper Fusible Link

Loading...

Round Damper Fusible Link

Loading...
Note: Product availability is real-time basis and adjusted continuously. The product will be reserved for you when you complete your order.
Back to Top