Fan & Limit Controls
Available130 products
Fan and limit controls dictate when the blower fan operates to ensure furnace systems run efficiently and safely. They feature a temperature sensor that can turn off the burner or furnace if temperatures exceed safe limits. They come in several different form factors that allow for installation in several places throughout the heating system.
Plenum Fan & Limit Controls
Plenum fan and limit controls mount into the wall of a plenum and control when the blower fan is turned on and off. They feature a temperature probe that inserts through a hole in the plenum and measures the temperature of the furnace airstream. Depending on their configuration, they can have fixed or adjustable trigger temperatures.
Fan and Limit Control
Automatic Reset
Loading... |
Plenum Limit Controls
Plenum limit controls mount through the wall of a duct or furnace plenum and turn the fan off when the trigger temperature is reached. They feature a large base with notches or holes for mounting hardware to pass through and hold them in place. This provides the temperature probe with a solid base to withstand high airflow. They are commonly used as protection devices to turn systems on or off when temperatures exceed or drop below their setpoint.
Limit Control – Board Mount
Automatic Reset
Loading... |
Limit Control – Plenum Mount
Manual Reset
Loading... |
Surface Mount Limit Controls
Surface mount limit controls provide fail-safe controls for temperatures above the safety limit. They operate using temperature-sensitive metals that change shape and disconnect the connected circuit when the trigger temperature is reached. They are installed on flat surfaces using two mounting holes and fasteners to hold them in place. Depending on their configuration, their trigger temperature can be fixed or adjusted, and their reset can be manual or automatic. They are commonly used as protection devices to turn systems on or off when temperatures exceed or drop below their setpoint.
Limit Control
Automatic Reset
Loading... | |||||
Loading... |
Manual Reset
Loading... |
Adjustable Limit Control
Automatic Reset
Loading... |
Limit Control with Fan Bypass
Automatic Reset
Loading... |
Surface Mount Fan Controls
These fan controls mount to flat surfaces and operate fans based on surrounding air temperature. When the air temperature is cooled sufficiently, they stop the fan to ensure it only runs when needed to improve overall system efficiency.
Fan Control
Automatic Reset
Loading... |
Flame Rollout Limit Controls
Flame rollout limit controls are installed into a furnace or combustion heater and turn the system off when flames are detected outside the combustion area. This prevents furnace runaway and flames from spreading beyond the combustion area.
Flame Rollout
Manual Reset
Loading... |