Navigation Menu New

Access My Account, Order History, Lists and more here.

Hazardous Location Sealing Fittings

Available4 products

Sealing fittings join pieces of heavy-wall RMC and medium-wall IMC metal conduit together or to enclosures and hold a seal around wire within the conduit. They minimize the passage of gases and vapors and prevent the passage of flames from one electrical installation to another through the conduit system. They also restrict explosions to the sealed-off enclosure and prevent pressure from piling up in the conduit system. These fittings are used in hazardous industrial locations, such as petroleum refineries, gasoline storage areas, and petrochemical facilities.

Brand

Vertical Sealing Fittings - 25% Fill

Vertical Sealing Fittings - 25% Fill
Sealing fittings join pieces of RMC and IMC conduit together and can be used in a vertical orientation only. They have a 25% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female to Female Threaded Ends

Loading...

Male to Female Threaded Ends

Loading...
Note: Product availability is real-time basis and adjusted continuously. The product will be reserved for you when you complete your order.